4.0 Configuration
When enabled the data will continue to buffer received on the
serial data port when the radio loses synchronization. When
disabled the VIP4G will disregard any data received on the
serial data port when radio synchronization is lost.
No-Connection Data
Values (selection)
Disable / Enable
This option will enable or disable the MODBUS decoding and
encoding features.
MODBUS TCP Status
Values (selection)
Disable / Enable
The field allows the MODBUS TCP Protection Status flag to be
enabled or disabled. If enabled the MODBUS data will be
encrypted with the MODBUS Protection Key.
MODBUS TCP Protection
Values (selection)
Disable / Enable
MODBUS encryption key used for the MODBUS TCP
Protection Status feature.
MODBUS TCP Protection Key
Values (string)